Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2015, 07:56 AM
  • 22 0298_22 0297_20151230_001629.mp4

Date
12/29/2015
W/O
547382
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16584
Time
11:56 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3020
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_547382_TV22014_JAN2016
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 0297
Downstream MH
22 0298
Dir. of Survey
Upstream
Length Surveyed
431.4 ft.
Total Length
431.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 22 0297 to 22 0298
MH: 22 0297MH: 22 0298upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 02983.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish3.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.3 ft. MGO - General Observation - MAGNESIUM H.O. FINISH44.5 ft. VC - Vermin Cockroach44.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"48.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"124.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"128.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"180.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"199.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"240.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"272.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"309.3 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"329.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"361.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"394.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"423 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE428.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start428.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start428.4 ft. MGO - General Observation - MAGNESIUM H.O. START431.4 ft. MWL - Water Level, 10 %of cross sectional area431.4 ft. MWM - Water Mark, 10 %of cross sectional area431.4 ft. AMH - Downstream Manhole, Survey Begins - 22 0297

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
3DAGS
191.3TFA
0MWL
0MWM
428.1DAGS
428.1SAP
251TFA
386.9VC
36.7TFC
302.6TFA
158.6TFA
3SAP
382.8TFA
0AMH22 0297
101.9TFC
3MGOMAGNESIUM H.O. START
69.5TF
122.1TFA
428.1MGOMAGNESIUM H.O. FINISH
232TFA
8.4TFDROOTS INSIDE
431.4AMH22 0298
386.9TFC
306.5TFC

Properties (5)

additional_info
SC224612
custom_field_two
3
customer
LACSD
datetime
2015-12-29T23:56:02-08:00
sewer_category