Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 2, 2016, 11:21 AM
  • 02 1469_02 1468 _20160802_052851.mp4

Date
08/02/2016
W/O
585991
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00309
PipeID
P03913
Time
4:21 AM
Certificate
507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3670
Sewer Name
02 UNION PACIFIC TRUNK
City
COMMERCE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
WO_585991_TV02189_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1468
Downstream MH
02 1469
Dir. of Survey
Upstream
Length Surveyed
212.7 ft.
Total Length
212.7 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1468 to 02 1469
MH: 02 1468MH: 02 1469upstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE 12 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 02 1469111.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"158.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"159.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"203.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"211.7 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES212.7 ft. AMH - Downstream Manhole, Survey Begins - 02 1468212.7 ft. MWL - Water Level, 5 %of cross sectional area212.7 ft. MWM - Water Mark, 10 %of cross sectional area

Observations (10)

DistanceCodeObservation
53TFC
1CL
0AMH02 1468
54.1TF
212.7MGOCONNECTION AT MANHOLE 12 O'CLOCK
8.9TF
0MWL
101.4TFC
212.7AMH02 1469
0MWM

Properties (5)

additional_info
SC305550
custom_field_two
4
customer
LACSD
datetime
2016-08-02T04:21:00-07:00
sewer_category