Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 2, 2016, 06:05 AM
  • 02 1477_02 1476 _20160802_001739.mp4

Date
08/01/2016
W/O
585991
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00309
PipeID
P03921
Time
11:05 PM
Certificate
507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3670
Sewer Name
02 UNION PACIFIC TRUNK
City
COMMERCE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_585991_TV02189_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1477
Downstream MH
02 1476
Dir. of Survey
Downstream
Length Surveyed
269.7 ft.
Total Length
269.7 ft.
Structural Index
2
Structural Quick
2400
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1477 to 02 1476
MH: 02 1477MH: 02 1476downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 1477 (23:03)0 ft. MWL - Water Level, 5 %of cross sectional area7.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES81.1 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES82.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"103.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"130.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"157.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"181.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"212.5 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES220.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"246.2 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES269.7 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE269.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1476269.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE

Observation photos (2)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    82.5 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    246.2 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
82.5TF
220.6TFA
130.2TFC
7.3CL
0MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
103.9TFC
157.5TFC
269.7MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
269.7AMH02 1476
269.7MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
0MGOCONNECTION AT THE MH 3 O'CLOCK ACTIVE
81.1CL
212.5CL
0MWM
181.2TF
0AMH02 1477 (23:03)
0MWL
246.2CL

Properties (5)

additional_info
SC305550
custom_field_two
4
customer
LACSD
datetime
2016-08-01T23:05:00-07:00
sewer_category
Gravity