02 1480_02 1479A _20160803_023454.mp4
0 ft. - Water Level, 5 %of cross sectional area
1 ft. - Deposits Attached Ragging, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES
1 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"
31.2 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"
174.8 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"
255.5 ft. - Deposits Settled Gravel, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 256.4 | VC | — |
| 170.7 | CL | — |
| 19.4 | DSGV | — |
| 1 | DAR | — |
| 123.6 | TFC | — |
| 174.8 | TF | — |
| 0 | MWM | — |
| 256.4 | AMH | 02 1480 |
| 1 | TBA | — |
| 31.2 | TFA | — |
| 0 | MWL | — |
| 255.5 | DSGV | — |
| 72.6 | TFA | — |
| 148 | TFC | — |
| 0 | AMH | 02 1479A |
| 0 | MGO | CONNECTION AT THE MH 3 O'CLOCK ACTIVE |
| 96.8 | TFC | — |