- Date
- 08/02/2016
- W/O
- 585991
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00309
- PipeID
- P04629
- Time
- 10:51 PM
- Certificate
- 507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3671
- Sewer Name
- 02 UNION PACIFIC TRUNK
- City
- COMMERCE, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_585991_TV02189_AUG2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 1462
- Downstream MH
- 02 1461
- Dir. of Survey
- Downstream
- Length Surveyed
- 262.1 ft.
- Total Length
- 262.1 ft.
- Structural Index
- 2
- Structural Quick
- 2111
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 02 1462 to 02 1461 Observation photos (3)

0 ft. - Water Mark, 15 %of cross sectional area

4.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

92 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 3"