Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2016, 05:51 AM
  • 02 1462_02 1461 _20160803_000634.mp4

Date
08/02/2016
W/O
585991
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00309
PipeID
P04629
Time
10:51 PM
Certificate
507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3671
Sewer Name
02 UNION PACIFIC TRUNK
City
COMMERCE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
WO_585991_TV02189_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1462
Downstream MH
02 1461
Dir. of Survey
Downstream
Length Surveyed
262.1 ft.
Total Length
262.1 ft.
Structural Index
2
Structural Quick
2111
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 1462 to 02 1461
MH: 02 1462MH: 02 1461downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14624.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start82.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"89.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"92 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 3"110.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start113.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"117.4 ft. CC - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES128.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"130.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish141.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"161.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"171 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"189 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"213.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"234.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"238.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"259.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"260.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish262.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1461

Observation photos (3)

  • Water Mark, 15 %of cross sectional area

    0 ft. - Water Mark, 15 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    4.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 3"

    92 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 3"

Observations (23)

DistanceCodeObservation
189TFC
130.4CL
171TFC
0MWL
0MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
92TB
0MWM
0AMH02 1462
259.1TFC
238.1TFA
213.3TFC
161.9TFC
4.7DAGS
260.1DAGS
89.1TFC
141.2TFC
234.7TFC
128.5TF
82.7TFA
117.4CC
110.9CL
262.1AMH02 1461
113.5TFC

Properties (5)

additional_info
SC306001
custom_field_two
3
customer
LACSD
datetime
2016-08-02T22:51:00-07:00
sewer_category
Gravity