02 1597_02 1596_20160816_003039.mpg
0 ft. - General Observation - CONNECTION AT THE MH 3 O'CLOCK
0 ft. - General Observation - CONNECTION AT THE MH 9 O'CLOCK

0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
106.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"
150.9 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"
199.4 ft. - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"
204.9 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"
231.6 ft. - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 4"
| Distance | Code | Observation |
|---|---|---|
| 325.5 | MGO | CONNECTION AT THE MH 12 O'CLOCK |
| 150.9 | TFC | — |
| 325.3 | DAGS | — |
| 0 | MWL | — |
| 199.4 | TFC | — |
| 0 | VC | — |
| 325.7 | MGO | CONNECTION AT THE MH 3 O'CLOCK |
| 0 | AMH | 02 1597 |
| 204.9 | TFC | — |
| 0 | MGO | CONNECTION AT THE MH 3 O'CLOCK |
| 0 | MGO | CONNECTION AT THE MH 9 O'CLOCK |
| 0 | DAGS | — |
| 325.7 | VC | — |
| 106.1 | TFC | — |
| 0 | MWM | — |
| 231.6 | TFB | — |
| 325.7 | AMH | 02 1596 |