Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 16, 2016, 08:54 AM
  • 02 1593_02 1592A_20160816_030504.mpg

Date
08/16/2016
W/O
585987
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00231
PipeID
P04048
Time
1:54 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3420
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 2
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_585987_TV02010_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1593
Downstream MH
02 1592A
Dir. of Survey
Downstream
Length Surveyed
136 ft.
Total Length
136 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2D11
O&M Rating
55
Overall Index
2
Overall Quick
Overall Rating
57
Pipe schematic from manhole 02 1593 to 02 1592A
MH: 02 1593MH: 02 1592Adownstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15930 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start74 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES77.8 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"136 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK136 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish136 ft. AMH - Downstream Manhole, Survey Ends - 02 1592A

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    74 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    77.8 ft. - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

    104.9 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

Observations (11)

DistanceCodeObservation
2DAGS
104.9TBA
0MWL
136MGOCONNECTION AT THE MH 9 O'CLOCK
136DAGS
0AMH02 1593
77.8TFB
0VC
136AMH02 1592A
74CL
0MWM

Properties (5)

additional_info
SC305973
custom_field_two
4
customer
LACSD
datetime
2016-08-16T01:54:41-07:00
sewer_category
Gravity