Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 29, 2015, 07:00 AM
  • 21 1060_21 1059_20151228_232957.mp4

Date
12/28/2015
W/O
547133
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00769
PipeID
P16185
Time
11:00 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3019
Sewer Name
21 GAREY AVENUE TRUNK
City
POMONA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
06
Purpose
Routine Assessment
Project
WO_547133_TV21036_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
21 1060
Downstream MH
21 1059
Dir. of Survey
Downstream
Length Surveyed
318.3 ft.
Total Length
318.3 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
1
O&M Quick
211C
O&M Rating
24
Overall Index
1
Overall Quick
Overall Rating
26
Pipe schematic from manhole 21 1060 to 21 1059
MH: 21 1060MH: 21 1059downstream0 ft. MGO - General Observation - ROOTS AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 21 10600 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES6.6 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES22.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES39.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES40.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"54.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES91.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"103 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"105.5 ft. RFJ - Roots Fine Joint, from 09 to 11 o'clock, within 8 inches of joint: YES113.3 ft. RFJ - Roots Fine Joint, from 12 to 04 o'clock, within 8 inches of joint: YES117.7 ft. RFJ - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YES139.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE153.2 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YES157.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES177.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES189.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES190.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE216.5 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES221.1 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES221.1 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES233 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES242.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"243.9 ft. RFJ - Roots Fine Joint, from 08 to 11 o'clock, within 8 inches of joint: YES252.1 ft. RFJ - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YES260.5 ft. RFJ - Roots Fine Joint, from 08 to 12 o'clock, within 8 inches of joint: YES268.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES280.7 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES290.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"299.8 ft. RFJ - Roots Fine Joint, from 09 to 11 o'clock, within 8 inches of joint: YES315 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish318.3 ft. AMH - Downstream Manhole, Survey Ends - 21 1059

Observation photos (1)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    177.6 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (37)

DistanceCodeObservation
0MGOROOTS AT MH
233RFJ
299.8RFJ
0AMH21 1060
290.3TFC
0MWM
260.5RFJ
40.4TFC
280.7RFJ
22.7RFJ
268.4RFJ
216.5RFJ
139.2TFCROOTS INSIDE
54.2RFJ
103TBA
177.6CL
39.3RFJ
113.3RFJ
2.4RFJ
105.5RFJ
189.7RFJ
252.1RFJ
117.7RFJ
153.2RFJ
2.1DAGS
6.6RFJ
242.5TFC
315DAGS
221.1RFJ
91.9TFC
221.1RFJ
0VC
243.9RFJ
157.2RFJ
318.3AMH21 1059
190.9TFCROOTS INSIDE
0MWL

Properties (5)

additional_info
SC224611
custom_field_two
4
customer
LACSD
datetime
2015-12-28T23:00:30-08:00
sewer_category
SIPHON