Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2015, 11:42 AM
  • 21 1062_21 1061_20151228_044246.mp4

Date
12/28/2015
W/O
547133
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00769
PipeID
P16187
Time
3:42 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3018
Sewer Name
21 GAREY AVENUE TRUNK
City
PRO PIPE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
06
Purpose
Routine Assessment
Project
WO_547133_TV21036_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
21 1062
Downstream MH
21 1061
Dir. of Survey
Downstream
Length Surveyed
380.9 ft.
Total Length
380.9 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
1
O&M Quick
2316
O&M Rating
12
Overall Index
1
Overall Quick
Overall Rating
14
Pipe schematic from manhole 21 1062 to 21 1061
MH: 21 1062MH: 21 1061downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 21 10620 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 10 %of cross sectional area2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start66.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"118.7 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE166.1 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE169.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"169.9 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES218 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"223.3 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES227.4 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES227.4 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES264 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES265.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE274.9 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES317.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE372.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"377.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish380.9 ft. AMH - Downstream Manhole, Survey Ends - 21 1061

Observation photos (1)

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    169.9 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
264RFJ
169.9CL
377.6DAGS
372.5TFC
227.4RFJ
380.9AMH21 1061
0MWM
169.6TBA
317.1TFCROOTS INSIDE
0MGOLATERAL AT MH 9 O'CLOCK ACTIVE
0AMH21 1062
66.9TFC
265.8TFCROOTS INSIDE
0VC
118.7TFDROOTS INSIDE
227.4RFJ
218TFC
0MWL
223.3RFJ
166.1TFDROOTS INSIDE
2.2DAGS
274.9RFJ

Properties (5)

additional_info
SC224610
custom_field_two
4
customer
LACSD
datetime
2015-12-28T03:42:56-08:00
sewer_category
SIPHON