- Date
- 01/12/2016
- W/O
- 547108
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00521
- PipeID
- P05950
- Time
- 10:48 PM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3113
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
- City
- INGLEWOOD, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_547108_TV05104_JAN2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 05 0727
- Downstream MH
- 05 0726
- Dir. of Survey
- Downstream
- Length Surveyed
- 84.7 ft.
- Total Length
- 84.7 ft.
- Structural Index
- 3
- Structural Quick
- 4131
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 05 0727 to 05 0726 Observation photos (3)

1 ft. - Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES

7.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

27.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start