Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2016, 08:11 AM
  • 05 0728_05 0727_20160113_002706_.mp4

Date
01/13/2016
W/O
547108
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00521
PipeID
P05951
Time
12:11 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3113
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
City
INGLEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_547108_TV05104_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
05 0727
Downstream MH
05 0728
Dir. of Survey
Upstream
Length Surveyed
145 ft.
Total Length
145 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
3
O&M Quick
4131
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 05 0727 to 05 0728
MH: 05 0727MH: 05 0728upstream0 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR, Finish0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - DUE TO LARGE ROOT BALL0 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish1 ft. RBJ - Roots Ball Joint, from 01 to 11 o'clock, 70 %, within 8 inches of joint: YES7.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"7.3 ft. RFL - Roots Fine Lateral, at 02 o'clock9.8 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR, Start27.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"42.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"129.7 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start135.1 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES142 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start145 ft. AMH - Downstream Manhole, Survey Begins - 05 0727145 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK145 ft. MWM - Water Mark, 25 %of cross sectional area145 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK145 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (6)

  • Water Mark, 25 %of cross sectional area

    0 ft. - Water Mark, 25 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

    9.9 ft. - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    15.3 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR, Start

    135.2 ft. - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR, Start

  • Roots Ball Joint, from 01 to 11 o'clock, 70 %, within 8 inches of joint: YES

    144 ft. - Roots Ball Joint, from 01 to 11 o'clock, 70 %, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
0AMH05 0727
9.9CM
135.2RMJ
145RMJ
15.3CM
0MGOCONNECTION AT MH 3 OCLOCK
0MWM
144RBJ
145DAGS
117.1TFC
145MSADUE TO LARGE ROOT BALL
145CM
137.7TFC
0MGOCONNECTION AT MH 9 OCLOCK
102.4TBA
137.7RFL
0MWL
3DAGS

Properties (4)

additional_info
SC224495
custom_field_two
5
customer
LACSD
datetime
2016-01-13T00:11:00-08:00