Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2016, 09:50 AM
  • 32 1080_32 1079_03022016_015109.mp4

Date
02/03/2016
W/O
547105
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19529
Time
1:50 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3091
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
32 1080
Downstream MH
32 1079
Dir. of Survey
Downstream
Length Surveyed
271.6 ft.
Total Length
271.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
322J
O&M Rating
116
Overall Index
2
Overall Quick
Overall Rating
119
Pipe schematic from manhole 32 1080 to 32 1079
MH: 32 1080MH: 32 1079downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 32 10805.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.8 ft. MWM - Water Mark, 35 %of cross sectional area40.2 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"64.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"101 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"143.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"153.7 ft. FS - Fracture Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES162 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"216.2 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS216.3 ft. RML - Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES222.5 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS222.6 ft. RML - Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES264.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"269.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish271.6 ft. AMH - Downstream Manhole, Survey Ends - 32 1079271.6 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    5.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES

    153.7 ft. - Fracture Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    216.2 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES

    216.3 ft. - Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    222.5 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES

    222.6 ft. - Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
143.6TFA
153.7FS
0MWL
222.5TFDROOTS
5.8DAGS
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0AMH32 1080
101TFA
162TFA
216.2TFDROOTS
269.5DAGS
264.9TFA
271.6AMH32 1079
5.8MWM
222.6RML
271.6MGOACTIVE CONNECTION AT MH 3 O'CLOCK
216.3RML
40.2TFA
64.4TFA

Properties (5)

additional_info
SC225469
custom_field_two
4
customer
LACSD
datetime
2016-02-03T01:50:28-08:00
sewer_category