Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2016, 08:50 AM
  • 32 1098_32 1097_02022016_005131.mp4

Date
02/02/2016
W/O
547105
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19547
Time
12:50 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3090
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
32 1097
Downstream MH
32 1098
Dir. of Survey
Upstream
Length Surveyed
345.1 ft.
Total Length
345.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
141
Pipe schematic from manhole 32 1097 to 32 1098
MH: 32 1097MH: 32 1098upstream0 ft. AMH - Upstream Manhole, Survey Ends - 32 10982 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES19.2 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"43 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"59 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"101.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"158.7 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"169.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"343.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start345.1 ft. MWL - Water Level, 5 %of cross sectional area345.1 ft. AMH - Downstream Manhole, Survey Begins - 32 1097345.1 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

    325.9 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 1"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    342.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MWL
302.1TBA
345.1AMH32 1098
0AMH32 1097
342.5CM
286.1TBA
186.4TBA
176TFC
325.9TBI
2DAGS
243.2TFC
291.9TFC
0MWM
343.1DAGS

Properties (5)

additional_info
SC225468
custom_field_two
4
customer
LACSD
datetime
2016-02-02T00:50:20-08:00
sewer_category
GRAVITY