Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 4, 2016, 06:54 AM
  • 32 1070_32 1069_03022016_225513.mp4

Date
02/03/2016
W/O
547105
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19518
Time
10:54 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3092
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
32 1070
Downstream MH
32 1069
Dir. of Survey
Downstream
Length Surveyed
244.4 ft.
Total Length
244.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
322I
O&M Rating
103
Overall Index
2
Overall Quick
Overall Rating
103
Pipe schematic from manhole 32 1070 to 32 1069
MH: 32 1070MH: 32 1069downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 10700 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"30.4 ft. TBD - Tap Break-In Defective, at 01 o'clock, -, , within 8 inches of joint: NO, 6" - ROOTS38.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"44 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"116.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"122.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"194.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"200 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"215 ft. TBD - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 6" - ROOTS215 ft. RFL - Roots Fine Lateral, from 11 to 01 o'clock217.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"242.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish244.4 ft. AMH - Downstream Manhole, Survey Ends - 32 1069

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Defective, at 01 o'clock, -,  , within 8 inches of joint: NO, 6" - ROOTS

    30.4 ft. - Tap Break-In Defective, at 01 o'clock, -, , within 8 inches of joint: NO, 6" - ROOTS

  • Tap Break-In Defective, at 12 o'clock, -,  , within 8 inches of joint: YES, 6" - ROOTS

    215 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 6" - ROOTS

  • Roots Fine Lateral, from 11 to 01 o'clock

    215 ft. - Roots Fine Lateral, from 11 to 01 o'clock

Observations (17)

DistanceCodeObservation
38.8TFC
122.2TFC
2DAGS
217.1TBA
194.6TFC
116.7TFC
0AMH32 1070
242.3DAGS
44TFC
215TBDROOTS
30.4TBDROOTS
0MWL
244.4AMH32 1069
0MWM
3TFC
200TFC
215RFL

Properties (5)

additional_info
SC225470
custom_field_two
4
customer
LACSD
datetime
2016-02-03T22:54:45-08:00
sewer_category
GRAVITY