Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2016, 10:16 AM
  • 32 1100_32 1099_02022016_021630.mp4

Date
02/02/2016
W/O
547105
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19549
Time
2:16 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3090
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
32 1100
Downstream MH
32 1099
Dir. of Survey
Downstream
Length Surveyed
297.6 ft.
Total Length
297.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
121
Pipe schematic from manhole 32 1100 to 32 1099
MH: 32 1100MH: 32 1099downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 11000 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start22.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"101.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"186.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"277.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"295.6 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES296.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish297.6 ft. AMH - Downstream Manhole, Survey Ends - 32 1099

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    295.6 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
296.8DAGS
186.2TFC
0AMH32 1100
277.8TFC
2DAGS
0MWM
22.4TFC
295.6CM
0MWL
297.6AMH32 1099
101.3TFC

Properties (5)

additional_info
SC225468
custom_field_two
4
customer
LACSD
datetime
2016-02-02T02:16:06-08:00
sewer_category
GRAVITY