Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2016, 12:10 PM
  • 32 1064_32 1063_01022016_041118.mp4

Date
02/01/2016
W/O
547105
Weather
Light Rain
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19512
Time
4:10 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3089
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
05
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
32 1063
Downstream MH
32 1064
Dir. of Survey
Upstream
Length Surveyed
222.8 ft.
Total Length
222.8 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2H00
O&M Rating
90
Overall Index
2
Overall Quick
Overall Rating
92
Pipe schematic from manhole 32 1063 to 32 1064
MH: 32 1063MH: 32 1064upstream0 ft. AMH - Upstream Manhole, Survey Ends - 32 10640.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish25.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"32.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"67.8 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"103.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"155.6 ft. CS - Crack Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES181.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"187 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS220.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start222.8 ft. MWM - Water Mark, 35 %of cross sectional area222.8 ft. AMH - Downstream Manhole, Survey Begins - 32 1063222.8 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    35.8 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Crack Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES

    67.2 ft. - Crack Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
155TBA
197.2TFC
67.2CS
222.6DAGS
222.8AMH32 1064
119TFA
41TFA
190.6TFC
0MWM
0AMH32 1063
113.3TFC
2DAGS
0MWL
35.8TFDROOTS

Properties (5)

additional_info
SC225467
custom_field_two
4
customer
LACSD
datetime
2016-02-01T04:10:53-08:00
sewer_category
GRAVITY