Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2016, 07:52 AM
  • 32 1107_32 1106_28012016_235246.mp4

Date
01/28/2016
W/O
547105
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19557
Time
11:52 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3088
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
32 1107
Downstream MH
32 1106
Dir. of Survey
Downstream
Length Surveyed
300.2 ft.
Total Length
300.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412K
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
122
Pipe schematic from manhole 32 1107 to 32 1106
MH: 32 1107MH: 32 1106downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 11072 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start49 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"191.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"298.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish300.2 ft. AMH - Downstream Manhole, Survey Ends - 32 1106

Observations (8)

DistanceCodeObservation
0MWL
49TFA
2DAGS
298.3DAGS
0MWM
0AMH32 1107
300.2AMH32 1106
191.3TFA

Properties (5)

additional_info
SC225466
custom_field_two
4
customer
LACSD
datetime
2016-01-28T23:52:25-08:00
sewer_category
GRAVITY