Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2016, 01:41 PM
  • 32 1059_32 1058_01022016_054147.mp4

Date
02/01/2016
W/O
547105
Weather
Light Rain
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19507
Time
5:41 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3089
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
05
Purpose
Routine Assessment
Project
WO_547105_TV32026_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
32 1059
Downstream MH
32 1058
Dir. of Survey
Downstream
Length Surveyed
154.2 ft.
Total Length
154.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412E
O&M Rating
64
Overall Index
2
Overall Quick
Overall Rating
64
Pipe schematic from manhole 32 1059 to 32 1058
MH: 32 1059MH: 32 1058downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 10592 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start25.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"57.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"99.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"129 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish154.2 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK154.2 ft. AMH - Downstream Manhole, Survey Ends - 32 1058

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
154.2MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
25.8TFC
0MWM
2DAGS
0AMH32 1059
154.2AMH32 1058
152.4DAGS
129TFC
57.6TFC
99.7TFC

Properties (5)

additional_info
SC225467
custom_field_two
4
customer
LACSD
datetime
2016-02-01T05:41:31-08:00
sewer_category
GRAVITY