Wastewater/Activity/PacpInspection/1.0Sep 6, 2016, 09:19 AM
  • 01 0170B_01 0170A_06092016_021952.mp4

Date
09/06/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01199
Time
2:19 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3579
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0170B
Downstream MH
01 0170A
Dir. of Survey
Downstream
Length Surveyed
231.6 ft.
Total Length
231.6 ft.
Structural Index
3
Structural Quick
3722
Structural Rating
25
O&M Index
3
O&M Quick
3G21
O&M Rating
117
Overall Index
3
Overall Quick
Overall Rating
142
Pipe schematic from manhole 01 0170B to 01 0170A
MH: 01 0170BMH: 01 0170Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 0170B0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWL - Water Level, 5 %of cross sectional area11.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"18.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"36.2 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start45.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES53.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"56 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"101.4 ft. RFL - Roots Fine Lateral, at 02 o'clock101.4 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED103.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"146.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES153.5 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES161.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES190 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES196.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start211.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"217.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"222.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"228.4 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish228.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish231.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0170A231.6 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK

Observation photos (8)

  • Deposits Settled Fine,  15 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    36.2 ft. - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    45.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Lateral, at 02 o'clock

    101.4 ft. - Roots Fine Lateral, at 02 o'clock

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    146.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    153.5 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    161.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    190 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    210.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
210.4CM
0AMH01 0170B
161.5CL
190CM
217.6TFC
56TFC
0MWM
153.5CM
18.3TFC
231.6AMH01 0170A
211.3TFC
146.8CL
101.4RFL
11.9TF
0MGOLATERAL AT MH 3 OCLOCK
196.7TFC
222.5TF
45.1CM
101.4TFDCRACKED
103.7TFC
0MWL
228.4DSF
53.9TF
36.2DSF
228.4CM
231.6MGOLATERAL AT MH 3 OCLOCK
121.3TF

Properties (5)

additional_info
SC306169
custom_field_two
3
customer
LACSD
datetime
2016-09-06T02:19:25-07:00
sewer_category
Gravity