Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 7, 2016, 09:20 AM
  • 01 1363_01 1012_07092016_022037.mp4

Date
09/07/2016
W/O
585982
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00221
PipeID
P01859
Time
2:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3580
Sewer Name
01 VERNON EXTENSION TRUNK
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
WO_585982_TV01065_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 1012
Downstream MH
01 1363
Dir. of Survey
Upstream
Length Surveyed
275.1 ft.
Total Length
275.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 1012 to 01 1363
MH: 01 1012MH: 01 1363upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 136328.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"30.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"109.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"170 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES203.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"252.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.1 ft. MWM - Water Mark, 20 %of cross sectional area275.1 ft. MWL - Water Level, 15 %of cross sectional area275.1 ft. AMH - Downstream Manhole, Survey Begins - 01 1012

Observation photos (1)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    96.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
71.2TFC
165.7TF
244.7TFC
0MWM
105.1TF
0MWL
19.8TF
22.5TFC
169TFC
275.1AMH01 1363
246.8TFC
0AMH01 1012
96.9CL

Properties (5)

additional_info
SC306170
custom_field_two
4
customer
LACSD
datetime
2016-09-07T02:20:19-07:00
sewer_category