Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 27, 2016, 10:23 AM
  • 02 0891_02 0890 _062716_032409.mpg

Date
06/27/2016
W/O
580416
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00249
PipeID
P03460
Time
3:23 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3543
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_580416_TV02050_JULY2016
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0891
Downstream MH
02 0890
Dir. of Survey
Downstream
Length Surveyed
311.9 ft.
Total Length
311.9 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
186
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
186
Pipe schematic from manhole 02 0891 to 02 0890
MH: 02 0891MH: 02 0890downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 08910 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT THE MH CAPPED 9 O'CLOCK2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start34 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"130.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"139.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES141.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"230.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"290.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"308.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish311.9 ft. AMH - Downstream Manhole, Survey Ends - 02 0890

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    139.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
311.9AMH02 0890
0MWM
66.9TF
290.3TF
0MWL
130.6TFC
230.5TF
139.6CM
34TFC
0AMH02 0891
308.7SAP
190.4TF
141.2TF
2SAP
0MGOCONNECTION AT THE MH 3 O'CLOCK
0MGOCONNECTION AT THE MH CAPPED 9 O'CLOCK

Properties (5)

additional_info
SC305857
custom_field_two
3
customer
LACSD
datetime
2016-06-27T03:23:24-07:00
sewer_category
Gravity