- Date
- 02/05/2016
- W/O
- 547104
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00841
- PipeID
- P19485
- Time
- 2:49 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3094
- Sewer Name
- 32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
- City
- SANTA CLARITA
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 05
- Purpose
- V
- Project
- WO_547104_TV32025_JAN2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 32 1036
- Downstream MH
- 32 1037
- Dir. of Survey
- Upstream
- Length Surveyed
- 62.5 ft.
- Total Length
- 62.5 ft.
- Structural Index
- 4
- Structural Quick
- 4800
- Structural Rating
- 32
- O&M Index
- 2
- O&M Quick
- 312A
- O&M Rating
- 27
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 59
Pipe schematic from manhole 32 1036 to 32 1037 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

24.3 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

62.5 ft. - Survey Abandoned - DUE TO OBSTACLE/ROCK.

62.5 ft. - Obstacles Rocks, 20 %of cross sectional area, from 04 to 08 o'clock