Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 29, 2016, 09:49 AM
  • 18 0742_18 0741_20160429_025640.mpg

Date
04/29/2016
W/O
568699
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14595
Time
2:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3357
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_568699_TV18103_MAY2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
18 0742
Downstream MH
18 0741
Dir. of Survey
Downstream
Length Surveyed
213.2 ft.
Total Length
213.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0742 to 18 0741
MH: 18 0742MH: 18 0741downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 07420 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.4 ft. MGO - General Observation - MAG COAT 70%213.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0741

Observations (6)

DistanceCodeObservation
0AMH18 0742
2.4MGOMAG COAT 70%
0MGOCONNECTION AT MH 3 OCLOCK
0MWM
213.2AMH18 0741
0MWL

Properties (5)

additional_info
SC300353
custom_field_two
3
customer
LACSD
datetime
2016-04-29T02:49:46-07:00
sewer_category