- Date
- 01/26/2016
- W/O
- 547569
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z01180
- PipeID
- P01476
- Time
- 3:40 AM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3126
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- RFIR_WO_547569_TV01236_JAN2016
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- G 0153
- Downstream MH
- G 0152
- Dir. of Survey
- Downstream
- Length Surveyed
- 294.4 ft.
- Total Length
- 294.4 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2J00
- O&M Rating
- 114
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 114
Pipe schematic from manhole G 0153 to G 0152 Observation photos (2)

7 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

55.6 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"