Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2016, 09:45 AM
  • 14 0240_14 0239A_28012016_014520.mp4

Date
01/28/2016
W/O
547519
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00569
PipeID
P18293
Time
1:45 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3086
Sewer Name
14 AVENUE "H" TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_547519_TV14071_JAN2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
14 0240
Downstream MH
14 0239A
Dir. of Survey
Downstream
Length Surveyed
102.3 ft.
Total Length
102.3 ft.
Structural Index
3
Structural Quick
3C2C
Structural Rating
100
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
104
Pipe schematic from manhole 14 0240 to 14 0239A
MH: 14 0240MH: 14 0239Adownstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 02400 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. MGO - General Observation - MAG COATING 60%2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start100.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE100.6 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish100.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish102.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK102.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0239A

Observation photos (3)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    100.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
100.6MGOCOCKROACHES IN MANHOLE
2MGOMAG COATING 60%
102.3MGOACTIVE CONNECTION AT MH 9 O'CLOCK
2SAV
100.6SAV
102.3AMH14 0239A
100.6SSS
2SSS
0MWL
0AMH14 0240
0MWM

Properties (5)

additional_info
SC225464
custom_field_two
3
customer
LACSD
datetime
2016-01-28T01:45:06-08:00
sewer_category