Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2016, 12:24 PM
  • 19 0074_C 0376_20160309_054538.mpg

Date
03/09/2016
W/O
557873
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00724
PipeID
P15106
Time
4:24 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3220
Sewer Name
19 ELAINE AVENUE TRUNK
City
LAKEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
WO_557873_TV19004_2016MAR
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0074
Downstream MH
C 0376
Dir. of Survey
Downstream
Length Surveyed
307.2 ft.
Total Length
307.2 ft.
Structural Index
3
Structural Quick
4331
Structural Rating
33
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole 19 0074 to C 0376
MH: 19 0074MH: C 0376downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 00749.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES77.3 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Start97.5 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Finish98.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 11 o'clock, , within 8 inches of joint: YES102 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"140.7 ft. MWLS - Water Level, Sag in pipe, 25 %of cross sectional area, Start147 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES155.3 ft. MWLS - Water Level, Sag in pipe, 25 %of cross sectional area, Finish171.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"207 ft. FM - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES215.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES227.8 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area, Start232.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES235.3 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area, Finish303.2 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES303.2 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 07 to 12 o'clock, , within 8 inches of joint: YES307.2 ft. AMH - Downstream Manhole, Survey Ends - C 0376

Observation photos (9)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    9.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 11 o'clock,  , within 8 inches of joint: YES

    98.8 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 11 o'clock, , within 8 inches of joint: YES

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    102 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Water Level, Sag in pipe, 25 %of cross sectional area, Start

    140.7 ft. - Water Level, Sag in pipe, 25 %of cross sectional area, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    147 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    207 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    215.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    232.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    303.2 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
235.3MWLS
227.8MWLS
232.8CL
171.9TBA
147FM
0MWL
307.2AMHC 0376
9.8DAGS
303.2FM
207FM
102TBA
77.3MWLS
303.2DAE
98.8DAE
0MWM
215.8CM
0AMH19 0074
155.3MWLS
140.7MWLS
97.5MWLS

Properties (5)

additional_info
SC305310
custom_field_two
3
customer
LACSD
datetime
2016-03-09T04:24:01-08:00
sewer_category