Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2016, 08:01 AM
  • 18 0379_18 0378_20160323_012440.mp4

Date
03/23/2016
W/O
557580
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00690
PipeID
P14213
Time
1:01 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3233
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK, CA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_557580_TV18095_2016MAR
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
18 0379
Downstream MH
18 0378
Dir. of Survey
Downstream
Length Surveyed
351.3 ft.
Total Length
351.3 ft.
Structural Index
4
Structural Quick
4332
Structural Rating
18
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 18 0379 to 18 0378
MH: 18 0379MH: 18 0378downstream0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 03797.1 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES7.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start12 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES16.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES21.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"27.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start40 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start40 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish91.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"105.1 ft. MGP - General Photograph182.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"288.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"294 ft. MGP - General Photograph342.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"347 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish347 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish351.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0378

Observation photos (12)

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    7.1 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    7.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    12 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    16.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    27.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    40 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"

    91.2 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"

  • General Photograph

    105.1 ft. - General Photograph

  • General Photograph

    294 ft. - General Photograph

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    347 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

  • Downstream Manhole, Survey Ends - 18 0378

    351.3 ft. - Downstream Manhole, Survey Ends - 18 0378

Observations (21)

DistanceCodeObservation
21.2TFC
27.3CM
288.2TFC
91.2TFC
294MGP
347FM
7.2DAGS
40FM
0MGOLATERAL AT MH 3 OCLOCK
40CM
105.1MGP
347DAGS
12FM
351.3AMH18 0378
0MWM
342.9TFC
0MWL
7.1FM
182.7TFC
16.1CM
0AMH18 0379

Properties (5)

additional_info
SC305324
custom_field_two
2
customer
LACSD
datetime
2016-03-23T01:01:44-07:00
sewer_category