Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 4, 2016, 09:09 AM
  • 29 0822_29 0331_20160304_021637.mp4

Date
03/04/2016
W/O
557696
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01017
PipeID
P25791
Time
1:09 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3217
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
WO_557696_TV29045_2016MAR
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0331
Downstream MH
29 0822
Dir. of Survey
Upstream
Length Surveyed
100.8 ft.
Total Length
100.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0331 to 29 0822
MH: 29 0331MH: 29 0822upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 08220 ft. VC - Vermin Cockroach, within 8 inches of joint: YES5.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"23.8 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 4"34.6 ft. DNGV - Deposits Ingress Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish42.2 ft. DNGV - Deposits Ingress Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start100.8 ft. MWL - Water Level, 5 %of cross sectional area100.8 ft. VC - Vermin Cockroach100.8 ft. AMH - Downstream Manhole, Survey Begins - 29 0331100.8 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • Deposits Ingress Gravel,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    58.6 ft. - Deposits Ingress Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
0VC
58.6DNGV
0AMH29 0331
66.2DNGV
100.8AMH29 0822
77TFA
95.4TFA
0MWM
100.8VC

Properties (5)

additional_info
SC305306
custom_field_two
4
customer
LACSD
datetime
2016-03-04T01:09:23-08:00
sewer_category