Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2017, 08:04 AM
  • J 0069_J 0067_3152017_021934.mp4

Date
03/15/2017
W/O
0613633
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00063
PipeID
P11648
Time
1:04 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0465
Sewer Name
J JOINT OUTFALL J - UNIT 2D
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
31
Purpose
Capital Improvement Program Assesment
Project
20170313MDM_JOINT_OUTFALL_J_UNIT_2D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
J 0069
Downstream MH
J 0067
Dir. of Survey
Downstream
Length Surveyed
560.8 ft.
Total Length
560.8 ft.
Structural Index
3
Structural Quick
3423
Structural Rating
18
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
18
Pipe schematic from manhole J 0069 to J 0067
MH: J 0069MH: J 0067downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING PEELING CONCRETE2 ft. MGO - General Observation - MAG COAT 70% START 8:00 TO 4:0017.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG32.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE35.3 ft. MGO - General Observation - MAG COAT 20% START72.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES89.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open217.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC291 ft. MGO - General Observation - MAG COAT 70% START312.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG334.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active489 ft. MGO - General Observation - 50% MAG COAT START560.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC560.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING,FLAKING ,PEELING CONCRETE560.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active560.2 ft. MGO - General Observation - MAG COAT 50% FINISH560.8 ft. AMH - Downstream Manhole, Survey Ends - 2:35AM

Observation photos (11)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING PEELING CONCRETE

  • General Observation - MAG COAT 70% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 70% START 8:00 TO 4:00

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    17.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    32.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • General Observation - MAG COAT 20% START

    35.3 ft. - General Observation - MAG COAT 20% START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    72.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    217.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • General Observation - MAG COAT 70% START

    291 ft. - General Observation - MAG COAT 70% START

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    312.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Observation - 50% MAG COAT START

    489 ft. - General Observation - 50% MAG COAT START

Observations (22)

DistanceCodeObservation
2SAVSEVERE AGG SPORATIC
32.9SSSPEELING CONCRETE
560.2SAVSEVERE AGG SPORATIC
312.7SAVSEVERE AGG
72.8SSS
291MGOMAG COAT 70% START
560.2SSSBLISTERING,FLAKING ,PEELING CONCRETE
560.2MGOConn. @ Mh, 9 O' Clock. Active
334.9TFActive
0AMH1:55AM
2SSSFLAKING PEELING CONCRETE
2MGOMAG COAT 70% START 8:00 TO 4:00
35.3MGOMAG COAT 20% START
217.1SAVSEVERE AGG SPORATIC
17.7SAVSEVERE AGG
560.2MGOMAG COAT 50% FINISH
560.8AMH2:35AM
89.2TFOpen
489MGO50% MAG COAT START
0MWL
0MWM
0MGOConn. @ Mh, 9 O' Clock. Active

Properties (4)

custom_field_three
SEVERE AGG SPORATIC
custom_field_two
3
customer
LACSD
datetime
2017-03-15T01:04:26-07:00