Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2016, 03:23 PM
  • A 1090_A 0580_20160114_072659.mp4

Date
01/14/2016
W/O
541844
Weather
Dry
Operator/Surveyor
ERUIZ
Sewer ID
Z00316
PipeID
P22156
Time
7:23 AM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2296
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
HACIENDA HEIGHTS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_541844_TV21027_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Upstream MH
A 1090
Downstream MH
A 0580
Dir. of Survey
Downstream
Length Surveyed
12.1 ft.
Total Length
12.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole A 1090 to A 0580
MH: A 1090MH: A 0580downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 07248.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES12.1 ft. AMH - Downstream Manhole, Survey Ends - 0726

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    8.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
0MWL
8.2SAP
12.1AMH0726
0MWM
0AMH0724

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-01-14T07:23:42-08:00
sewer_category
TRANSITION
year_laid
19951017