Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 21, 2017, 08:31 AM
  • J 0062_J 0061_3212017_015134.mp4

Date
03/21/2017
W/O
0613633
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00063
PipeID
P11640
Time
1:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0472
Sewer Name
J JOINT OUTFALL J - UNIT 2D
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Capital Improvement Program Assesment
Project
20170317MDM_JOINT_OUTFALL_J_UNIT_2D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
J 0062
Downstream MH
J 0061
Dir. of Survey
Downstream
Length Surveyed
937.5 ft.
Total Length
937.5 ft.
Structural Index
3
Structural Quick
3524
Structural Rating
23
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole J 0062 to J 0061
MH: J 0062MH: J 0061downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC2 ft. MGO - General Observation - MAG COAT 30% START 8:00 TO 4:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING ,PEELING CONCRETE14.3 ft. SAV - Surface Aggregate Visible, from 08 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG56.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE CONCRETE134.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE143.6 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC204.7 ft. SSS - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE208.4 ft. MGP - General Photograph - PEELING CONCRETE291.2 ft. SAV - Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG464.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped582.8 ft. MGO - General Observation - MAG COAT 40% START657.3 ft. SAV - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG937.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE937.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG937.1 ft. MGO - General Observation - MAG COAT 40% FINISH937.5 ft. AMH - Downstream Manhole, Survey Ends - 2:45AM

Observation photos (12)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • General Observation - MAG COAT 30% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 30% START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING ,PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING ,PEELING CONCRETE

  • Surface Aggregate Visible, from 08 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

    14.3 ft. - Surface Aggregate Visible, from 08 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE CONCRETE

    56.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    134.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    143.6 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    204.7 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • General Photograph - PEELING CONCRETE

    208.4 ft. - General Photograph - PEELING CONCRETE

  • Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

    291.2 ft. - Surface Aggregate Visible, from 08 to 12 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • General Observation - MAG COAT 40% START

    582.8 ft. - General Observation - MAG COAT 40% START

  • Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    657.3 ft. - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (21)

DistanceCodeObservation
582.8MGOMAG COAT 40% START
464.8TFCapped
204.7SSSPEELING CONCRETE
56.9SSSPEELING CONCRETE CONCRETE
937.5AMH2:45AM
134.8SSSBLISTERING CONCRETE
937.1SSSBLISTERING PEELING CONCRETE
937.1SAVSEVERE AGG
937.1MGOMAG COAT 40% FINISH
0MGOConn. @ Mh, 3 O' Clock. Capped
0MWM
0MWL
0AMH1:45AM
2SAVSEVERE AGG SPORATIC
143.6SAVSEVERE AGG SPORATIC
2MGOMAG COAT 30% START 8:00 TO 4:00
14.3SAVSEVERE AGG
2SSSBLISTERING ,PEELING CONCRETE
208.4MGPPEELING CONCRETE
291.2SAVSEVERE AGG
657.3SAVSEVERE AGG

Properties (4)

custom_field_three
SEVERE AGG VISIBLE
custom_field_two
3
customer
LACSD
datetime
2017-03-21T01:31:12-07:00