Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 16, 2017, 09:55 AM
  • 02 1697_02 1696_3162017_025921.mp4

Date
03/16/2017
W/O
0613355
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00289
PipeID
P18855
Time
2:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0468
Sewer Name
02 MONTEREY PARK EXTENSION TRUNK
City
MONTERY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
06
Purpose
Routine Assessment
Project
20170316MDM_MONTERY_PARK_EXTENSION_PARK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1697
Downstream MH
02 1696
Dir. of Survey
Downstream
Length Surveyed
345.4 ft.
Total Length
345.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 1697 to 02 1696
MH: 02 1697MH: 02 1696downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:55AM189.9 ft. DAE - Deposits Attached Encrustation, 3 %of cross sectional area, from 12 to 04 o'clock, , within 8 inches of joint: YES189.9 ft. IW - Infiltration Weeper, from 12 to 02 o'clock, within 8 inches of joint: YES198.3 ft. MGO - General Observation - 15" VCP345.4 ft. AMH - Downstream Manhole, Survey Ends - 3:30AM

Observation photos (1)

  • General Observation - 15" VCP

    198.3 ft. - General Observation - 15" VCP

Observations (7)

DistanceCodeObservation
189.9DAE
0MWL
198.3MGO15" VCP
0MWM
0AMH2:55AM
345.4AMH3:30AM
189.9IW

Properties (3)