Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2017, 03:49 PM
  • 29 0337_29 0332_3152017_092513.mp4

Date
03/15/2017
W/O
0624617
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z01017
PipeID
P24356
Time
8:49 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7361
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
20170314DF_PACIFIC_COAST_HIGHWAY_SEWER
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
29 0337
Downstream MH
29 0332
Dir. of Survey
Downstream
Length Surveyed
325 ft.
Total Length
325 ft.
Structural Index
3
Structural Quick
5139
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
34
Pipe schematic from manhole 29 0337 to 29 0332
MH: 29 0337MH: 29 0332downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. UNKNOWN0 ft. AMH - Upstream Manhole, Survey Begins - 9:10 AM0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.2 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES24.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"26.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES50.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4" - OPEN62.1 ft. FL - Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES81.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN/75% GREASE100.3 ft. MGP - General Photograph - SPALLING145.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open/60% GREASE173.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - Open/85% GREASE204.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"247.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN/85% GREASE257.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - Open/60% GREASE272.1 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES284.1 ft. B - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES284.9 ft. MGP - General Photograph - FRACTURES286.1 ft. H - Hole, at 12 o'clock, within 8 inches of joint: YES295.3 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES320.9 ft. FS - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES322.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish323.9 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active324.8 ft. AMH - Downstream Manhole, Survey Begins - 10:24 AM325 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES

    11.2 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    26.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES

    62.1 ft. - Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES

  • General Photograph - SPALLING

    100.3 ft. - General Photograph - SPALLING

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    272.1 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

    284.1 ft. - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

  • General Photograph - FRACTURES

    284.9 ft. - General Photograph - FRACTURES

  • Hole, at 12 o'clock, within 8 inches of joint: YES

    286.1 ft. - Hole, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    295.3 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    320.9 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

Observations (31)

DistanceCodeObservation
284.1B
325MGOConn. @ Mh, 9 O' Clock. Active
173.4TFOpen/85% GREASE
62.1FL
323.9MGOConn. @ Mh, 3 O' Clock. Active
322.1SAV
0MWL
2SSS
0MGOConn. @ Mh, 9 O' Clock. UNKNOWN
50.2TFOPEN
320.9FS
295.3CM
322.1CM
0AMH9:10 AM
284.9MGPFRACTURES
0MWM
322.1SSS
272.1CM
11.2FS
145.1TFOpen/60% GREASE
286.1H
81.2TFOPEN/75% GREASE
2SAV
2CM
204.1TFA
24.6TFA
257.8TFOpen/60% GREASE
247.6TFUNKNOWN/85% GREASE
100.3MGPSPALLING
324.8AMH10:24 AM
26.3FL

Properties (3)

custom_field_two
1
customer
LACSD
datetime
2017-03-15T08:49:13-07:00