- Date
- 12/14/2015
- W/O
- 541799
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00704
- PipeID
- P14231
- Time
- 3:30 AM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K2887
- Sewer Name
- 18 SORENSEN AVENUE RELIEF TRUNK
- City
- WHITTIER, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_541799_TV18054_DEC2015
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 18 0553
- Downstream MH
- 18 0395
- Dir. of Survey
- Downstream
- Length Surveyed
- 1 ft.
- Total Length
- 1 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 18 0553 to 18 0395 Observation photos (2)

1 ft. - Survey Abandoned - DUE TO DEBRIS

1 ft. - Deposits Settled Fine, 75 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO