Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2015, 06:52 AM
  • 14 0406_14 0405_22122015_225227.mp4

Date
12/22/2015
W/O
541759
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00578
PipeID
P18489
Time
10:52 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3056
Sewer Name
14 TRUNK "B"
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
Routine Assessment
Project
WO_541759_TV14063_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
14 0406
Downstream MH
14 0405
Dir. of Survey
Downstream
Length Surveyed
350.2 ft.
Total Length
350.2 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
204
O&M Index
2
O&M Quick
412M
O&M Rating
142
Overall Index
3
Overall Quick
Overall Rating
346
Pipe schematic from manhole 14 0406 to 14 0405
MH: 14 0406MH: 14 0405downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 04060 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CAPPED CONNECTION AT MH 9 O'CLOCK2 ft. MGO - General Observation - MAG COATING 80% THROUGHOUT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start348.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish350.2 ft. AMH - Downstream Manhole, Survey Ends - 14 0405

Observations (8)

DistanceCodeObservation
2MGOMAG COATING 80% THROUGHOUT
350.2AMH14 0405
0MWL
0AMH14 0406
2DAGS
0MWM
0MGOCAPPED CONNECTION AT MH 9 O'CLOCK
348.4DAGS

Properties (5)

additional_info
SC204195
custom_field_two
4
customer
LACSD
datetime
2015-12-22T22:52:02-08:00
sewer_category
GRAVITY