05 1113_05 1092_552017_112935.mp4
3.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
6.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
127.2 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES
175.3 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
323 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
365.6 ft. - General Observation - CONNECTION AT MH, 3 OCLOCK, ACTIVE
365.7 ft. - General Observation - CONNECTION AT MH, 9 OCLOCK, OPEN
365.8 ft. - Downstream Manhole, Survey Ends - 11:51 AM
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 11:30 AM |
| 127.2 | SSS | — |
| 365.6 | MGO | CONNECTION AT MH, 3 OCLOCK, ACTIVE |
| 364.1 | SSS | — |
| 0 | MWL | — |
| 364.1 | DAGS | — |
| 3.9 | SSS | — |
| 365.8 | AMH | 11:51 AM |
| 365.7 | MGO | CONNECTION AT MH, 9 OCLOCK, OPEN |
| 175.3 | TBA | — |
| 6.3 | DAGS | — |
| 323 | CM | — |
| 0 | MWM | — |