05 1116_05 1115_542017_120809.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
88.2 ft. - General Photograph - SPALLING
123.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
200.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES
210.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
236.4 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES
241.2 ft. - General Observation - SPALLING
255.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 256.4 | SSS | — |
| 260.7 | AMH | 12:33 PM |
| 260.7 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 255.3 | DAGS | — |
| 0 | AMH | 12:00 PM |
| 260.7 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 0 | MGO | ROACHES @ MH |
| 241.2 | MGO | SPALLING |
| 0 | MWL | — |
| 123.7 | CL | — |
| 200.3 | CL | — |
| 88.2 | MGP | SPALLING |
| 2 | SSS | — |
| 210.6 | CL | — |
| 260.7 | MGO | ROACHES @ MH |
| 0 | MWM | — |
| 236.4 | CM | — |