14 0435_14 0434_23122015_222530.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
48.6 ft. - Material Change, Concrete pipe (non-reinfored) - NRCP
48.7 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
49.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
65.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
81.5 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES
100.3 ft. - Survey Abandoned - DUE TO DEBRIS/OBSTACLE
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 49.1 | SSS | — |
| 100.3 | SSS | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 9 O'CLOCK |
| 100.3 | DAGS | — |
| 0 | MWL | — |
| 81.5 | DSZ | — |
| 2 | DAGS | — |
| 48.7 | SAV | — |
| 0 | AMH | 14 0435 |
| 100.3 | SAV | — |
| 48.6 | MMC | NRCP |
| 100.3 | SAP | — |
| 65.9 | SAP | — |
| 15 | TFC | — |
| 100.3 | MSA | DUE TO DEBRIS/OBSTACLE |
| 0 | MGO | RUN LIST STATES NRCP |