- Date
- 01/25/2016
- W/O
- 541735
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00471
- PipeID
- P06953
- Time
- 4:18 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K2780
- Sewer Name
- 05 LOMITA TRUNK
- City
- LOMITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- WO_541735_TV05197_DEC2015
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 05 1726
- Downstream MH
- 05 1725
- Dir. of Survey
- Downstream
- Length Surveyed
- 318.5 ft.
- Total Length
- 318.5 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole 05 1726 to 05 1725 Observation photos (4)

8.8 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES

125.3 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO

183.2 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

254.9 ft. - Crack Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES