Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 1, 2017, 08:37 AM
  • 01 0442_01 0441_512017_033057.mp4

Date
05/01/2017
W/O
0624632
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00208
PipeID
P00924
Time
1:37 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0511
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
201700501MDM_HOLMES_WILLOWBROOK_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
01 0442
Downstream MH
01 0441
Dir. of Survey
Downstream
Length Surveyed
347.5 ft.
Total Length
347.5 ft.
Structural Index
3
Structural Quick
4334
Structural Rating
30
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
33
Pipe schematic from manhole 01 0442 to 01 0441
MH: 01 0442MH: 01 0441downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 60% START 9:00 TO 3:0028.1 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-SLIGHT FRACTURES37.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG37.7 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE37.7 ft. MGO - General Observation - MAG COAT 60% START 8:00 TO 4:0037.7 ft. MWM - Water Mark, 20 %of cross sectional area37.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG66.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active69.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE POSSIBLE SEVERE AGG ATTCHED76.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open79.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped79.8 ft. MGO - General Observation - MAG COAT 10% START92.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open115.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELED AWAY CONCRETE126 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped127 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open135.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active139.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped150.5 ft. SSS - Surface Spalling, from 01 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE182.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open193 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open200.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open218.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open218.8 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR - 2%222.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT244.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open267.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped273.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open282.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG290.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open309.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT317.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT321.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open342.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open347 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE POSSIBLE SEVERE AGG ATTACHED347 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG347 ft. MGO - General Observation - MAG COAT 10% FINISH347.5 ft. AMH - Downstream Manhole, Survey Ends - 4:15AM

Observation photos (12)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 60% START 9:00 TO 3:00

    2 ft. - General Observation - MAG COAT 60% START 9:00 TO 3:00

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-SLIGHT FRACTURES

    28.1 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-SLIGHT FRACTURES

  • General Observation - MAG COAT 60% START 8:00 TO 4:00

    37.7 ft. - General Observation - MAG COAT 60% START 8:00 TO 4:00

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    37.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE POSSIBLE  SEVERE AGG ATTCHED

    69.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE POSSIBLE SEVERE AGG ATTCHED

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELED AWAY CONCRETE

    115.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELED AWAY CONCRETE

  • Surface Spalling, from 01 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    150.5 ft. - Surface Spalling, from 01 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    222.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    282.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    309.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    317.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (42)

DistanceCodeObservation
150.5SSSPEELING CONCRETE
347SSSPEELING CONCRETE POSSIBLE SEVERE AGG ATTACHED
273.3TFOpen
182.8TFOpen
115.8SSSPEELED AWAY CONCRETE
37.7SAVSEVERE
347SAVSEVERE AGG
79.8TFCCapped
218.8TFOpen
347MGOMAG COAT 10% FINISH
200.7TFOpen
282.6SAVSEVERE AGG
37.1SAVSEVERE AGG
37.7MGOMAG COAT 60% START 8:00 TO 4:00
139.3TFCCapped
309.7FMSLIGHT
347.5AMH4:15AM
66.3TBActive
321.5TFOpen
2SAVSEVERE AGG
135.9TBActive
76.7TFOpen
126TFCCapped
0AMH3:30AM
92.7TFOpen
244.5TFOpen
0MWL
37.7MWM
79.8MGOMAG COAT 10% START
0MWM
218.8RFJ2%
290.7TFOpen
37.7SAVSEVERE AGG
222.3FMSLIGHT
342.4TFOpen
127TBOpen
2MGOMAG COAT 60% START 9:00 TO 3:00
267.4TFCCapped
317.9FMSLIGHT
28.1TFDOpen-SLIGHT FRACTURES
193TFOpen
69.6SSSPEELING CONCRETE POSSIBLE SEVERE AGG ATTCHED

Properties (4)

custom_field_three
PEELING CONCRETE POSSIBLE SEVERE AGG ATTCHES
custom_field_two
2
customer
LACSD
datetime
2017-05-01T01:37:38-07:00