Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2017, 08:53 AM
  • B 0622_B 0621_542017_024758.mp4

Date
05/04/2017
W/O
0624373
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00107
PipeID
P09287
Time
1:53 AM
Certificate
U-1-14-06O22543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0515
Sewer Name
B JOINT OUTFALL B - UNIT 8D
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
20170503MDM_JOINT_OUTFALL_B_UNIT_8D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
B 0622
Downstream MH
B 0621
Dir. of Survey
Downstream
Length Surveyed
417.6 ft.
Total Length
417.6 ft.
Structural Index
3
Structural Quick
3622
Structural Rating
22
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
26
Pipe schematic from manhole B 0622 to B 0621
MH: B 0622MH: B 0621downstream0 ft. MGO - General Observation - MAG COAT 15% START 9:00 TO 3:000 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:50AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN,FLAKING CONCRETE14.3 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC24.1 ft. SAV - Surface Aggregate Visible, from 11 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC52 ft. MGO - General Observation - MAG COAT 40% START71 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC79 ft. SAV - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC118.4 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC126.7 ft. SAV - Surface Aggregate Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC383.3 ft. MGO - General Observation - MAG COAT 20% START390.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN,FLAKING CONCRETE417.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active417.1 ft. MGO - General Observation - MAG COAT 20% FINISH417.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SWOLLEN,FLAKING CONCRETE417.6 ft. AMH - Downstream Manhole, Survey Ends - 2:30AM

Observation photos (11)

  • General Observation - MAG COAT 15% START 9:00 TO 3:00

    0 ft. - General Observation - MAG COAT 15% START 9:00 TO 3:00

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN,FLAKING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN,FLAKING CONCRETE

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    14.3 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • Surface Aggregate Visible, from 11 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

    24.1 ft. - Surface Aggregate Visible, from 11 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

  • General Observation - MAG COAT 40% START

    52 ft. - General Observation - MAG COAT 40% START

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC

    71 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC

  • Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC

    79 ft. - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - SEVERE AG SPORATIC

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

    118.4 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

  • Surface Aggregate Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    126.7 ft. - Surface Aggregate Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • General Observation - MAG COAT 20% START

    383.3 ft. - General Observation - MAG COAT 20% START

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN,FLAKING CONCRETE

    390.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - SWOLLEN,FLAKING CONCRETE

Observations (20)

DistanceCodeObservation
0MGOMAG COAT 15% START 9:00 TO 3:00
0MGOConn. @ Mh, 3 O' Clock. Active
417.1MGOConn. @ Mh, 3 O' Clock. Active
24.1SAVSEVERE AGG SPORATIC
0MWM
383.3MGOMAG COAT 20% START
0MWL
417.1MGOMAG COAT 20% FINISH
390.1SSSSWOLLEN,FLAKING CONCRETE
417.1SSSSWOLLEN,FLAKING CONCRETE
0AMH2:50AM
14.3SAVSEVERE AGG SPORATIC
2SSSSWOLLEN,FLAKING CONCRETE
79SAVSEVERE AG SPORATIC
71SAVSEVERE AG SPORATIC
126.7SAVSEVERE AGG SPORATIC
118.4SAVSEVERE AGG SPORATIC
52MGOMAG COAT 40% START
0MGOConn. @ Mh, 9 O' Clock. Capped
417.6AMH2:30AM

Properties (4)

custom_field_three
SPALLING CONCRETE-FEW SEVERE AGG
custom_field_two
4
customer
LACSD
datetime
2017-05-04T01:53:21-07:00