Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2015, 08:27 AM
  • H 1274_H 1273_20151223_004549.mp4

Date
12/23/2015
W/O
536444
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01181
PipeID
P17199
Time
12:27 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2897
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
19
Purpose
Routine Assessment
Project
WO_536444_TV22032_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
H 1274
Downstream MH
H 1273
Dir. of Survey
Downstream
Length Surveyed
402.5 ft.
Total Length
402.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2O11
O&M Rating
159
Overall Index
2
Overall Quick
Overall Rating
162
Pipe schematic from manhole H 1274 to H 1273
MH: H 1274MH: H 1273downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 12740 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MGO - General Observation - BEGIN MAGNESIUM HYDROXIDE COATING2.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start21 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"61.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"93 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"100.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES116.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"156.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"204.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"220.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"276.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"292.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6"348.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"399.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish402.5 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 9 O'CLOCK402.5 ft. AMH - Downstream Manhole, Survey Ends - H 1273402.5 ft. VC - Vermin Cockroach

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    100.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
61.4TFA
292.8TFA
402.5MGOCONNECTION AT MANHOLE ACTIVE 9 O'CLOCK
402.5AMHH 1273
21TFC
2.9DAGS
402.5VC
348.1TFC
0MWL
0AMHH 1274
2MGOBEGIN MAGNESIUM HYDROXIDE COATING
204.8TFA
156.6TFA
399.7DAGS
220.7TFA
100.8SAV
93TFA
116.8TFA
0MWM
276.6TFA

Properties (5)

additional_info
SC224475
custom_field_two
3
customer
LACSD
datetime
2015-12-23T00:27:25-08:00
sewer_category