Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2016, 08:51 AM
  • H 1231_H 0586_20160106_005938.mp4

Date
01/06/2016
W/O
536444
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01181
PipeID
P17158
Time
12:51 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3106
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
WEST COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_536444_TV22032_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
H 1231
Downstream MH
H 0586
Dir. of Survey
Downstream
Length Surveyed
188.3 ft.
Total Length
188.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 1231 to H 0586
MH: H 1231MH: H 0586downstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - H 12310 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. MGO - General Observation - BEGIN MAGNESIUM HYDROXIDE COATING17.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"169.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.3 ft. AMH - Downstream Manhole, Survey Ends - H 0586

Observation photos (1)

  • Water Mark, 40 %of cross sectional area

    0 ft. - Water Mark, 40 %of cross sectional area

Observations (8)

DistanceCodeObservation
169.8TFA
0MGOCONNECTION AT MANHOLE ACTIVE 3 O'CLOCK
188.3AMHH 0586
2MGOBEGIN MAGNESIUM HYDROXIDE COATING
0AMHH 1231
0MWL
0MWM
17.4TFC

Properties (5)

additional_info
SC224486
custom_field_two
4
customer
LACSD
datetime
2016-01-06T00:51:00-08:00
sewer_category