Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 24, 2015, 11:28 AM
  • H 1234_H 1233_20151224_034350.mp4

Date
12/24/2015
W/O
536444
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01181
PipeID
P17159
Time
3:28 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2898
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
WEST COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_536444_TV22032_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
H 1234
Downstream MH
H 1233
Dir. of Survey
Downstream
Length Surveyed
431.4 ft.
Total Length
431.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole H 1234 to H 1233
MH: H 1234MH: H 1233downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 12340 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MGO - General Observation - BEGIN MAGNESIUM HYDROXIDE COATING36.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"69.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"76.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"125.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"133 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"149.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"172.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"220.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"236.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"252.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"292 ft. VC - Vermin Cockroach300.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"301.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"429.3 ft. MGO - General Observation - END MAG COATING431.4 ft. AMH - Downstream Manhole, Survey Ends - H 1233

Observations (19)

DistanceCodeObservation
300.4TFC
301.8TFA
2MGOBEGIN MAGNESIUM HYDROXIDE COATING
431.4AMHH 1233
76.8TFC
0AMHH 1234
149.1TFA
69.1TFA
125.1TFC
36.5TFA
220.6TFC
133TFC
0MWL
236.2TFC
429.3MGOEND MAG COATING
0MWM
172.4TFC
292VC
252.2TFC

Properties (5)

additional_info
SC224476
custom_field_two
4
customer
LACSD
datetime
2015-12-24T03:28:39-08:00
sewer_category
TRANSITION