Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2015, 11:48 AM
  • H 1248_H 1247_20151223_040640.mp4

Date
12/23/2015
W/O
536444
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01181
PipeID
P17173
Time
3:48 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2897
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
25
Purpose
Routine Assessment
Project
WO_536444_TV22032_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
H 1248
Downstream MH
H 1247
Dir. of Survey
Downstream
Length Surveyed
427.6 ft.
Total Length
427.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2P11
O&M Rating
167
Overall Index
2
Overall Quick
Overall Rating
167
Pipe schematic from manhole H 1248 to H 1247
MH: H 1248MH: H 1247downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 12482 ft. MGO - General Observation - BEGIN MAGNESIUM HYDROXIDE COATING3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start52.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"61 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"116.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"125.2 ft. RFC - Roots Fine Connection, at 02 o'clock, within 8 inches of joint: YES125.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"173.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"181 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"228.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"236.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"293.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"317.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"341.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"397.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"424.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish427.6 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 3 O'CLOCK427.6 ft. AMH - Downstream Manhole, Survey Ends - H 1247

Observations (22)

DistanceCodeObservation
7DAGS
0MWM
397.2TFA
341.4TFC
0MWL
116.8TFA
424.1DAGS
61TFA
427.6MGOCONNECTION AT MANHOLE ACTIVE 3 O'CLOCK
125.2RFC
181TFA
236.6TFA
427.6AMHH 1247
173.2TFA
293.4TFA
317.7TFA
2MGOBEGIN MAGNESIUM HYDROXIDE COATING
0AMHH 1248
228.9TFA
52.9TFA
3TFA
125.2TFA

Properties (5)

additional_info
SC224475
custom_field_two
4
customer
LACSD
datetime
2015-12-23T03:48:00-08:00
sewer_category
GRAVITY