Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 21, 2015, 11:47 AM
  • H 1249_H 1248_20151221_041826.mp4

Date
12/21/2015
W/O
536444
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01181
PipeID
P17174
Time
3:47 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2895
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
25
Purpose
Routine Assessment
Project
WO_536444_TV22032_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
H 1249
Downstream MH
H 1248
Dir. of Survey
Downstream
Length Surveyed
426.1 ft.
Total Length
426.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2P11
O&M Rating
171
Overall Index
2
Overall Quick
Overall Rating
171
Pipe schematic from manhole H 1249 to H 1248
MH: H 1249MH: H 1248downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 12490 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0.2 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 3 O'CLOCK2 ft. MGO - General Observation - BEGIN MAGNESIUM HYDROXIDE COATING2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start59.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"133.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"141.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"179.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"244.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"251.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"300 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"308.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"357.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"365 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"421.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"424.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish426.1 ft. AMH - Downstream Manhole, Survey Ends - H 1248426.1 ft. VC - Vermin Cockroach

Observations (22)

DistanceCodeObservation
179.5TFA
426.1AMHH 1248
0AMHH 1249
2MGOBEGIN MAGNESIUM HYDROXIDE COATING
426.1VC
357.1TFA
141.9TFA
0.2MGOCONNECTION AT MANHOLE ACTIVE 3 O'CLOCK
59.4TFA
187.2TFA
0MWM
251.3TFA
0MWL
421.1TFA
244.1TFA
308.4TFA
365TFA
300TFA
424.7DAGS
2DAGS
133.2TFA
67.9TFA

Properties (5)

additional_info
SC224473
custom_field_two
4
customer
LACSD
datetime
2015-12-21T03:47:00-08:00
sewer_category
GRAVITY