Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2016, 12:31 PM
  • 22 0092_22 0091_20160104_044610.mp4

Date
01/04/2016
W/O
531047
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00805
PipeID
P16333
Time
4:31 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2947
Sewer Name
22 DISTRICT #22 MAIN TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_531047_TV22092_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0092
Downstream MH
22 0091
Dir. of Survey
Downstream
Length Surveyed
333.1 ft.
Total Length
333.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 22 0092 to 22 0091
MH: 22 0092MH: 22 0091downstream0 ft. MGO - General Observation - MAGNEZIUM H.O. 40% START0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 009221.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"44.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"70.7 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"76.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"94.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"141.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"156.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"189.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"197.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"277.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"330 ft. MGO - General Observation - MAGNEZIUM H.O. 40% FINISH333.1 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK333.1 ft. VC - Vermin Cockroach333.1 ft. AMH - Downstream Manhole, Survey Ends - 22 0091

Observation photos (1)

  • General Observation - MAGNEZIUM H.O. 40% START

    0 ft. - General Observation - MAGNEZIUM H.O. 40% START

Observations (20)

DistanceCodeObservation
333.1MGOLATERAL AT MH 3 OCLOCK
0MGOMAGNEZIUM H.O. 40% START
277.7TFC
21.1TFC
330MGOMAGNEZIUM H.O. 40% FINISH
76.7TFC
189.4TFC
0VC
197.5TFC
0MWM
44.6TFC
0MGOLATERAL AT MH 3 OCLOCK ACTIVE
156.9TFC
70.7TBA
0MWL
333.1VC
0AMH22 0092
333.1AMH22 0091
141.6TFC
94.1TFC

Properties (5)

additional_info
SC224958
custom_field_two
4
customer
LACSD
datetime
2016-01-04T04:31:05-08:00
sewer_category