Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2016, 11:43 AM
  • 22 0094_22 0093_20160104_040919.mp4

Date
01/04/2016
W/O
531047
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00805
PipeID
P16335
Time
3:43 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2947
Sewer Name
22 DISTRICT #22 MAIN TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_531047_TV22092_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0094
Downstream MH
22 0093
Dir. of Survey
Downstream
Length Surveyed
333.3 ft.
Total Length
333.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 22 0094 to 22 0093
MH: 22 0094MH: 22 0093downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 00940 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. VC - Vermin Cockroach2 ft. MGO - General Observation - MAGNEZIUM H.O. 50% START4.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"13 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"20 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"36.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"77 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"85.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"133.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"142.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"165.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"173.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"206.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"221.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"254 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"287.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"330.7 ft. MGO - General Observation - MAGNEZIUM H.O. 50% FINISH333.2 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE333.3 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE333.3 ft. VC - Vermin Cockroach333.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0093

Observation photos (1)

  • General Observation - MAGNEZIUM H.O. 50% START

    2 ft. - General Observation - MAGNEZIUM H.O. 50% START

Observations (26)

DistanceCodeObservation
13TFC
36.7TFC
85.4TFC
0AMH22 0094
333.3MGOLATERAL AT MH 9 OCLOCK ACTIVE
254TFA
173.5TFC
165.5TFC
0MGOLATERAL AT MH 9 OCLOCK
0MWL
330.7MGOMAGNEZIUM H.O. 50% FINISH
77TFA
0MGOLATERAL AT MH 3 OCLOCK ACTIVE
133.9TFC
333.3VC
2MGOMAGNEZIUM H.O. 50% START
142.3TFC
287.1TFC
0MWM
221.5TFC
20TFC
333.3AMH22 0093
333.2MGOLATERAL AT MH 3 OCLOCK ACTIVE
4.4TFC
206.5TFC
0VC

Properties (5)

additional_info
SC224958
custom_field_two
4
customer
LACSD
datetime
2016-01-04T03:43:49-08:00
sewer_category
GRAVITY