Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2016, 10:55 AM
  • 22 0095_22 0094_20160104_034255.mp4

Date
01/04/2016
W/O
531047
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00805
PipeID
P16336
Time
2:55 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2947
Sewer Name
22 DISTRICT #22 MAIN TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_531047_TV22092_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0095
Downstream MH
22 0094
Dir. of Survey
Downstream
Length Surveyed
414.5 ft.
Total Length
414.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4111
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 22 0095 to 22 0094
MH: 22 0095MH: 22 0094downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 00952 ft. MGO - General Observation - MAGNEZIUM H.O. 50% START12.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"38.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"45.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"85.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"93.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"133.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"142 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"182 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"190.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"229.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"238.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"286.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"295 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"335.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"352 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"411.9 ft. MGO - General Observation - MAGNEZIUM H.O.50% FINISH414.5 ft. AMH - Downstream Manhole, Survey Ends - 22 0094414.5 ft. VC - Vermin Cockroach414.5 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE414.5 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE

Observation photos (1)

  • General Observation - MAGNEZIUM H.O. 50% START

    2 ft. - General Observation - MAGNEZIUM H.O. 50% START

Observations (24)

DistanceCodeObservation
182TFC
295TFC
142TFC
38.3TFC
0MWL
45.8TFC
229.7TFC
286.5TFC
0MWM
335.1TFA
238.7TF
414.5AMH22 0094
414.5VC
190.8TFC
414.5MGOLATERAL AT MH 9 OCLOCK ACTIVE
2MGOMAGNEZIUM H.O. 50% START
0AMH22 0095
352TFC
93.6TF
411.9MGOMAGNEZIUM H.O.50% FINISH
12.2TFC
414.5MGOLATERAL AT MH 3 OCLOCK ACTIVE
85.6TF
133.1TFC

Properties (5)

additional_info
SC224958
custom_field_two
4
customer
LACSD
datetime
2016-01-04T02:55:03-08:00
sewer_category
GRAVITY