Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2015, 07:58 AM
  • 01 0151_01 0150_09122015_235939.mp4

Date
12/09/2015
W/O
524985
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00204
PipeID
P02094
Time
11:58 PM
Certificate
12345
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2960
Sewer Name
01 COMPTON CREEK EXTENSION TRUNK, SECTION 2
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
WO_524985_TV011104_NOV2015
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 0151
Downstream MH
01 0150
Dir. of Survey
Downstream
Length Surveyed
353.4 ft.
Total Length
353.4 ft.
Structural Index
2
Structural Quick
3A27
Structural Rating
47
O&M Index
5
O&M Quick
5M42
O&M Rating
353
Overall Index
4
Overall Quick
Overall Rating
400
Pipe schematic from manhole 01 0151 to 01 0150
MH: 01 0151MH: 01 0150downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 01513.2 ft. DAGS - Deposits Attached Grease, 45 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start13 ft. CC - Crack Circumferential, from 12 to 06 o'clock, within 8 inches of joint: YES118.1 ft. CM - Crack Multiple, from 07 to 06 o'clock, within 8 inches of joint: YES123 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES133.3 ft. CM - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES137.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES137.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES142.5 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES158.2 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES167.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES174 ft. CM - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES189 ft. CS - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES194 ft. CC - Crack Circumferential, from 12 to 05 o'clock, within 8 inches of joint: YES198.9 ft. CM - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES206.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES210 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES213.6 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES224.7 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES228.7 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES255.5 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES305.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES326.4 ft. CC - Crack Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES350.2 ft. DAGS - Deposits Attached Grease, 45 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish352.9 ft. MGO - General Observation - CONNECTION AT MANHOLE353.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0150

Observation photos (20)

  • Crack Circumferential, from 12 to 06 o'clock, within 8 inches of joint: YES

    13 ft. - Crack Circumferential, from 12 to 06 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 06 o'clock, within 8 inches of joint: YES

    118.1 ft. - Crack Multiple, from 07 to 06 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    123 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    133.3 ft. - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    137.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    137.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    142.5 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    167.3 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    174 ft. - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

    189 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 12 to 05 o'clock, within 8 inches of joint: YES

    194 ft. - Crack Circumferential, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    198.9 ft. - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    206.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    210 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    213.6 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 25 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    224.7 ft. - Deposits Attached Grease, 25 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    228.7 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    255.5 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    305.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES

    326.4 ft. - Crack Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES

Observations (28)

DistanceCodeObservation
167.3CL
0MWL
0MWM
224.7DAGS
305.7CM
118.1CM
213.6CL
142.5CM
206.4CM
137.4CL
353.4AMH01 0150
350.2DAGS
158.2CL
3.2DAGS
228.7CL
194CC
137.4CL
352.9MGOCONNECTION AT MANHOLE
255.5CM
198.9CM
210CM
326.4CC
123CM
13CC
174CM
189CS
0AMH01 0151
133.3CM

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2015-12-09T23:58:40-08:00
sewer_category